Central line...bubble it


One of the more serious complications of central venous catheter (CVC) placement involves arterial puncture and cannullation with a large caliber dialator and catheter.  This occurs in up to 5% of all CVC placement attempts.  

Depending on the location of  CVC placement, inadvertent arterial placement may lead to bleeding, embolism, neurologic injury, airway loss and even death.  Verifying venous placement prior to dilatation, cannulation and infusion of vasoactive agents is essential.
One method of doing so in situations where placement is equivocal by standard methods is with the less-publicized but highly useful bedside echocardiography bubble test.
In order to employ this method during CVC placement, after the target vessel has been entered with the finder needle, insert the finder needle catheter.  Have an assistant place the echo probe in a subcostal position.  Through the finder needle catheter rapidly flush 10cc sterile saline (both agitated and non-agitated have been shown to work).  If the catheter is in the venous system, the right atrium and right ventricle will opacify almost immediately on echo.  If the catheter is in the arterial system, there will be a delay, and then the left atrium and left ventricle will be noted to opacify.
This method can help differentiate between arterial and venous cannulations prior to dilatation and placement of large bore catheters.  It can also be used once a catheter has been placed, to confirm venous placement.  By doing so the user to may confidently identify venous catheter placement prior to chest x-ray.  




Blaivas M.  “Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access.”  J Ultrasound Med 2009;28:1239-44.
Ghadiali N, Teo LM, Sheah K.  “Bedside confirmation of a persistent left superior vena cava based on aberrantly positioned central venous catheter on chest radiograph.” Br J Anaesth 2006;96:53–6.
Prekker ME, Chang R, Cole JB, Reardon R.  “Rapid confirmation of central venous catheter placement using an ultrasonographic "Bubble Test.” Acad Emerg Med 2010;17(7):e85-6.




Comments

Popular posts from this blog

Driving Pressure in ARDS: A new concept!

Driving Pressure and Survival in the Acute Respiratory Distress Syndrome Marcelo B.P. Amato, M.D., Maureen O. Meade, M.D., Arthur S. Slutsky, M.D., Laurent Brochard, M.D., Eduardo L.V. Costa, M.D., David A. Schoenfeld, Ph.D., Thomas E. Stewart, M.D., Matthias Briel, M.D., Daniel Talmor, M.D., M.P.H., Alain Mercat, M.D., Jean-Christophe M. Richard, M.D., Carlos R.R. Carvalho, M.D., and Roy G. Brower, M.D. N Engl J Med 2015; 372:747-755 February 19, 2015 DOI: 10.1056/NEJMsa1410639 BACKGROUND Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (V T ), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (C RS ) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size)...

Anaphylaxis updates part 2- Empty Ventricle Syndrome

Patients with anaphylaxis should not suddenly sit, stand, or be placed in the upright position. Instead, they should be placed on the back with their lower extremities elevated or, if they are experiencing respiratory distress or vomiting, they should be placed in a position of comfort with their lower extremities elevated. This accomplishes 2 therapeutic goals: 1) preservation of fluid in the circulation (the central vascular compartment), an important step in managing distributive shock; and 2) prevention of the empty vena cava/empty ventricle syndrome, which can occur within seconds when patients with anaphylaxis suddenly assume or are placed in an upright position. Patients with this syndrome are at high risk for sudden death. They are unlikely to respond to epinephrine regardless of route of administration, because it does not reach the heart and therefore cannot be circulated throughout the body

Epidural catheter tests...not only the test dose

Siphon test The catheter is held upright and a fluid level sought. If the catheter is then elevated, the fluid level should fall (see inset) as the fluid siphons in to the epidural space, which is usually under negative pressure compared with atmospheric. If the fluid column continues to rise, this may suggest subarachnoid placement. The siphon test can be reassuring, but is not mandatory. Aspiration  This should be considered mandatory. The Luer connector is attached to the catheter and a syringe is used to apply negative pressure. Free and continued aspiration of clear fluid can indicate subarachnoid placement of the catheter. However, if saline has been used for loss of resistance, it is not unusual for a small amount of this to be aspirated. If there is doubt, the aspirated fluid can be tested for glucose (cerebrospinal fluid will generally test positive) or mixed with thiopentone (cerebrospinal fluid forms a precipitate). If blood is freely and continuously aspirated, this sug...