Skip to main content

Skull Fracture and TBI..



According to a study in
J Trauma dec 2011,
the prescence of a skull fracture increases mortality in severe TBI by about 30%.







The study
Retrospective study of a total of 197 patients who had isolated severe TBI (GCS<9 at ED triage). The site was an university hospital. Paeds, multitrauma, traumatic cardiac arrest and no available CT images were exclusion criteria. Out of the 197 patients 46,7% had a skull fracture in the ED. 92 patients had a fractured skull while 105 patients comprised the non fractured group. These groups were compared for hospital mortality.

Results
Mortality in the skull fracture group was 64,1%.
Mortality in the non skull fracture group was 31,4%

Conclusion
Skull bone fracture might double mortality in severe TBI. Not surprising. Skull fractures imply the head was hit with energy high enough to break skull bones. Consequently, one would expect more severe tissue injury.


J Trauma. 2011 Dec;71(6):1611-4; discussion 1614

Comments

Popular posts from this blog

power injectable peripherally inserted central catheters

Clinical experience with power injectable peripherally inserted central catheters in intensive care patients     Introduction In intensive care units (ICU), peripherally inserted central catheters (PICC) may be an alternative option to standard central venous catheters, particularly in patients with coagulation disorders or at high risk for infection. Some limits of PICCs (such as low flow rates) may be overcome by the use of power-injectable catheters . Method We have retrospectively reviewed all the power injectable PICCs inserted in adult and pediatric patients in the ICU during a 12-month period, focusing on the rate of complications at insertion and during maintenance. Results We have collected 89 power injectable PICCs (in adults and in children), both multiple and single lumen. All insertions were successful. There were no major complications at insertion and no episodes of catheter-related blood stream infection. Non-infective complications ...

Things to Avoid in Anesthesia for Pregnant with Pulmonary hypertension

Anesthesia for Pregnant woman with Pulmonary Hypertension is a real challenge for anesthesiologist. It is very crucial to remember the pathophysiology of pulmonary hypertension in pregnant women and to avoid some practices that will worsen the cardiac status. 1-Avoid single shot spinal anesthesia. Some authorities consider pulmonary hypertension as absolute contraindication for single shot spinal anesthesia specially in patients with NYHA III ,IV. Spinal anesthesia causes major hemodynamic instability(decrease SVR, decrease VR, decrease in CO) The preferred neuroaxial techniques are (epidural anesthesia and CSE with minimal spinal dose) 2-Avoid PAC. Pulmonary Artery catheters insertion may lead to pulmonary artery rupture or thrombosis. TEE is better cardiac monitor/Arteial line is mandatory. 3-Avoid Nitrous oxide in gas mixture.N2O increase the PVR 4-If MV to be started, avoid High TV and PEEP 5-Avoid Oxytocin Boluses, or rapid administration of Pitocin. Oxytocin causes ...

Lumbar and thoracic epidural in Pediatrics-Technical aspect

The midline approach is most commonly used. The ligamentum   flavum is considerably thinner and less dense in infants than in older children and adults. This makes recognition of engagement in the ligament more difficult and requires both extra care and slower, more deliberate passage of the needle to avoid subarachnoid puncture. The angle of approach to the epidural space is slightly more perpendicular to the plane of the back than in older children and adults, owing to the orientation of the spinous   processes in infants and small children. The loss of resistance technique should be used, but only with saline, not air. There are several reports of venous air embolism in infants and children when air was used to test for loss of resistance Use a short (5 cm) 18-gauge Tuohy needle and a 20- or 21-gauge catheter in infants and children. Epidural kits specifically for infants and children are available Maximum of 0.4 mg/kg/hr of bupivacaine after the initial block is estab...