Skip to main content

Multiple anesthetics linked to ADHD!


Dr Sprung et al published a paper in the Mayo Clinic Proceedings entitled:

”Attention-Deficit/Hyperactivity Disorder After Early Exposure to Procedures Requiring General Anesthesia”

Abstract


Objective
To study the association between exposure to procedures performed under general anesthesia before age 2 years and development of attention-deficit/hyperactivity disorder (ADHD).

Patients and Methods
Study patients included all children born between January 1, 1976, and December 31, 1982, in Rochester, MN, who remained in Rochester after age 5. Cases of ADHD diagnosed before age 19 years were identified by applying stringent research criteria. Cox proportional hazards regression assessed exposure to procedures requiring general anesthesia (none, 1, 2 or more) as a predictor of ADHD using a stratified analysis with strata based on a propensity score including comorbid health conditions.

Results
Among the 5357 children analyzed, 341 ADHD cases were identified (estimated cumulative incidence, 7.6%; 95% confidence interval [CI], 6.8%-8.4%). For children with no postnatal exposure to procedures requiring anesthesia before the age of 2 years, the cumulative incidence of ADHD at age 19 years was 7.3% (95% CI, 6.5%-8.1%). For single and 2 or more exposures, the estimates were 10.7% ( 95% CI, 6.8%-14.4%) and 17.9% ( 95% CI, 7.2%-27.4%), respectively. After adjusting for gestational age, sex, birth weight, and comorbid health conditions, exposure to multiple (hazard ratio, 1.95; 95% CI, 1.03-3.71), but not single (hazard ratio,1.18; 95% CI, 0.79-1.77), procedures requiring general anesthesia was associated with an increased risk for ADHD.

Conclusion
Children repeatedly exposed to procedures requiring general anesthesia before age 2 years are at increased risk for the later development of ADHD even after adjusting for comorbidities.



Mayo Clinic Proceedings Volume 87, Issue 2, Pages 120-129, February 2012

Comments

Popular posts from this blog

Driving Pressure in ARDS: A new concept!

Driving Pressure and Survival in the Acute Respiratory Distress Syndrome Marcelo B.P. Amato, M.D., Maureen O. Meade, M.D., Arthur S. Slutsky, M.D., Laurent Brochard, M.D., Eduardo L.V. Costa, M.D., David A. Schoenfeld, Ph.D., Thomas E. Stewart, M.D., Matthias Briel, M.D., Daniel Talmor, M.D., M.P.H., Alain Mercat, M.D., Jean-Christophe M. Richard, M.D., Carlos R.R. Carvalho, M.D., and Roy G. Brower, M.D. N Engl J Med 2015; 372:747-755 February 19, 2015 DOI: 10.1056/NEJMsa1410639 BACKGROUND Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (V T ), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (C RS ) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size)...

Anaphylaxis updates part 2- Empty Ventricle Syndrome

Patients with anaphylaxis should not suddenly sit, stand, or be placed in the upright position. Instead, they should be placed on the back with their lower extremities elevated or, if they are experiencing respiratory distress or vomiting, they should be placed in a position of comfort with their lower extremities elevated. This accomplishes 2 therapeutic goals: 1) preservation of fluid in the circulation (the central vascular compartment), an important step in managing distributive shock; and 2) prevention of the empty vena cava/empty ventricle syndrome, which can occur within seconds when patients with anaphylaxis suddenly assume or are placed in an upright position. Patients with this syndrome are at high risk for sudden death. They are unlikely to respond to epinephrine regardless of route of administration, because it does not reach the heart and therefore cannot be circulated throughout the body

Epidural catheter tests...not only the test dose

Siphon test The catheter is held upright and a fluid level sought. If the catheter is then elevated, the fluid level should fall (see inset) as the fluid siphons in to the epidural space, which is usually under negative pressure compared with atmospheric. If the fluid column continues to rise, this may suggest subarachnoid placement. The siphon test can be reassuring, but is not mandatory. Aspiration  This should be considered mandatory. The Luer connector is attached to the catheter and a syringe is used to apply negative pressure. Free and continued aspiration of clear fluid can indicate subarachnoid placement of the catheter. However, if saline has been used for loss of resistance, it is not unusual for a small amount of this to be aspirated. If there is doubt, the aspirated fluid can be tested for glucose (cerebrospinal fluid will generally test positive) or mixed with thiopentone (cerebrospinal fluid forms a precipitate). If blood is freely and continuously aspirated, this sug...