intraosseous access , Beyond vascular access





The intraosseous access device (IO) has been a lifesaver by providing vascular access in patients who are difficult IV sticks. In some cases, it is even difficult to draw blood in these patients by a direct venipuncture. So is it okay to send IO blood to the lab for analysis during a trauma resuscitation?
A study using 10 volunteers was published last year (imagine volunteering to have an IO needle placed)! All IO devices were inserted in the proximal humerus. Here is a summary of the results comparing IO and IV blood:
  • Hemoglobin / hematocrit - good correlation
  • White blood cell count - no correlation
  • Platelet count - no correlation
  • Sodium - no correlation but within 5% of IV value
  • Potassium - no correlation
  • Choloride - good correlation
  • Serum CO2 - no correlation
  • Calcium - no correlation but within 10% of IV value
  • Glucose - good correlation
  • BUN / Creatinine - good correlation
Bottom line: Intraosseous blood can be used if blood from arterial or venous puncture is not available. Discarding the first 2cc of marrow aspirated improves the accuracy of the lab results obtained. The important tests (hemoglobin/hematocrit, glucose) are reasonably accurate, as are Na, Cl, BUN, and creatinine. The use of IO blood for type and cross is not yet widely accepted by blood banks, but can be used until other blood is available.
Reference: A new study of intraosseous blood for laboratory analysis. Arch Path Lab Med 134(9):1253-1260, 2010

 

Comments

Popular posts from this blog

The 100 essentials in icu and anesthesia

The most visual experience in anesthesia and critical care education  The 100 essentials of anesthesia and critical care  COMING VERY SOON  stay tuned 

Driving Pressure in ARDS: A new concept!

Driving Pressure and Survival in the Acute Respiratory Distress Syndrome Marcelo B.P. Amato, M.D., Maureen O. Meade, M.D., Arthur S. Slutsky, M.D., Laurent Brochard, M.D., Eduardo L.V. Costa, M.D., David A. Schoenfeld, Ph.D., Thomas E. Stewart, M.D., Matthias Briel, M.D., Daniel Talmor, M.D., M.P.H., Alain Mercat, M.D., Jean-Christophe M. Richard, M.D., Carlos R.R. Carvalho, M.D., and Roy G. Brower, M.D. N Engl J Med 2015; 372:747-755 February 19, 2015 DOI: 10.1056/NEJMsa1410639 BACKGROUND Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (V T ), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (C RS ) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size)...